Wiring Port
1.      +12 V working power Supply, input rang DC9-13.8V
2.     GND: Ground 
3.     NO:- Normally open relays, current carrying capacity DC10A/30V]
4.     COM:- Common pin of relays, current carrying capacity DC10A/30V
5.     NC:- Normally close relay, current carrying capacity DC10A/30V
6.     OPEN:-Button switch, low level May cause open.
7.     DOOR:- Door status detector, connected to the door detector, low level means door closed
8.     ALM:- Alarm output port, be low level when emergency occurs, currency is 100mA.
9.     WG0;- Wigand 26 reader data lines(data 0)
10. WG1:-Wigand 26 reader data lines(data 1) 
11. BELL:- the doorbell switch
Indicator:
1.     POWER: - Power indicator.
2.     MODE:-Mode light constantly means that has entered the management state MODE flashes means normal state.
3.     OK: - Ok Flashing means unlocked.
Reset Button (Reset)
Hold down the RESET button, wait for 2 seconds until beeps, release it, access controller would back to factory default status (management password back to 1234). After that, if hold RESET 5 second until beeps, release the RESET, it will initialize automatically and all the card data remote control manage password will be deleted and reset to factory defaults. Remove all cards; remove all the remote control, restoration of all parameters, recovery management password 1234)


Management of the state command table
Login *+Password+# default administrative password is 1234. Meanwhile the orange light (MODE) to light
Log off. Operation ** mode light flash.
1.       Add cards
add cards by entering the card number  10+#+8-bit card number.+# note card printed with "0012345678" just enter the card can be after the 8 digit 12345678.
Add password 11+ #+4-8 digit password +#.
Add stress password 12+ #+4-8 digit password +#.
Add card quickly: - 20+#card reading. Note can continuously cards one by one.
Add card by self number: - 21+#card reading+3 digit self-number.

    Note: - easy to remember, for example room number could be the self-number. if you need to add self -number continuously in press in press # and redo steps above
Add wireless remote control 22+#+ key on the remote control transmitter.
Note: - to get such a function, a 433MHZ frequency wireless module should be necessary.
Add Master Card:-23+#+ master card reading 

Note: - in the non -management state after master card reading once you can delete cards by reading. in the non-management state after the master card reading two times you can add cards by reading.
Add card packaged password 24+#+card reader + card 4-8 digit password+#.

2. Delete 
   Delete cards by reading 30+#+card reading
    indicate : the method can simultaneously read multiple consecutive delete the registered cards, as in the reader to stop for 10 seconds, the program will automatically exit the administrative state. 
  Delete cards by number 31+#+8 digit card number+#  
Note:- if the card is printed with "0012345678", just enter 12345678 can be deleted after the 8-bit cards.
   Delete cards by self-numbering 32+#+3 digit self-number+#
   Delete a wireless remote control 
33+#+press the "send key"
   Remove all wireless remote control 34+#
   Delete a password 35+# password+#
   Delete a all password 36+#
   Delete all data 40+# 
Note:- the access controller will be formatted , such as cards, passwords, wireless remote controls and other data will be removed completely.

3. Edit the parameters.
Edit the administrator password:-60+#+4-8 digit new administrator password +# +4-8 digit new administrator password.
Note: - the new password management change the password to confirm the new password twice, enter when the password should be the same twice, or not successful.
Edit the open period tips:-63+#+ 3 digit open period+# 
Note :- When the input 000 that means 0 second  has been set equal to close the open period prompts.(Maximum 999 second)
Edit the alarm time:-64+#+ 3 bit indicate the alarm time+# 
Note: - enter 000 (the default), turn off the alarm, enter 255 (255 is the maximum) the warning alarm would be continuously.
Edit the open Delay time:-66+#+ 3 bit open timeout+#
Note: - the input 000 means set to 0.5 seconds, the default is 3 seconds, the longest is 255 seconds.
 Anti-detection open password settings: - Operation types 68+#+1+2 bit error number+#
Note:- length of time input 999 (The default) self-locking  error 99 seconds 9.

4. Restore the factory default
70+#
Note: - command input all the parameters automatically after the restore the factory default values.( Remove all cards , remove all the remote control , restoration of all parameters, recovery management password:1234)

5. Keeping open and Quit command
Set the electric lock normally open:-83+#
Note: - after such an operation electric locks will not lock. (You can also press & hold open switch for 5 seconds to start the function)
Quit the electric lock normally closed set:-84+#
Note: - After such an operation to restore the default state. (You can also press & hold "Open switch button" for 5 seconds to restore the default state) 
6. Data Management
Data backup:-91+# 
Note the memory access data backup to the backup memory.
Data recovery 92+# 

Note a spare memory to access memory data recovery (while the original data access memory will be fully covered) memory model.
                                                                                                                                                                                      




Comments

Popular posts from this blog

download Tally erp 9 With nepali date

The security of data, financial or otherwise, has always been a matter of concern most business depend on the confidentiality of information. Tally vault is an enhanced security system which allows for encryption of the company data with the most secure method of encryption being use. Tally vault ensures that under no circumstances, the original information is available in any form. The techniques could be liked to "encryption - decryption on the fly" and decrypted form of the data is never stored in the system. Apart from this, it user the "Non-stored Password" mechanism. by using highly advanced mechanism to validate a new user without any prior knowledge of the original password. The combination of these facilities means, that Tally Vault becomes one of the most secure means of information storage.  Download tally erp 9 https://drive.google.com/open?id=1bqE6AkfU0UVSeGLRhGDpZRV5BJcfFaLR

How to assemble computer CPU Step by step || IT Tech

MCB box connection || IT TECH