1.
+12 V working
power Supply, input rang DC9-13.8V
2.
GND: Ground
3.
NO:- Normally open
relays, current carrying capacity DC10A/30V]
4.
COM:- Common pin of
relays, current carrying capacity DC10A/30V
5.
NC:- Normally close
relay, current carrying capacity DC10A/30V
6.
OPEN:-Button switch, low
level May cause open.
7.
DOOR:- Door status
detector, connected to the door detector, low level means door closed
8.
ALM:- Alarm output port,
be low level when emergency occurs, currency is 100mA.
9.
WG0;- Wigand 26 reader
data lines(data 0)
10.
WG1:-Wigand 26 reader
data lines(data 1)
11.
BELL:- the doorbell
switch
Indicator:
1.
POWER: - Power
indicator.
2.
MODE:-Mode light
constantly means that has entered the management state MODE flashes means
normal state.
3.
OK: - Ok Flashing means
unlocked.
Reset Button (Reset)
Hold down the RESET
button, wait for 2 seconds until beeps, release it, access controller would
back to factory default status (management password back to 1234). After that,
if hold RESET 5 second until beeps, release the RESET, it will initialize
automatically and all the card data remote control manage password will be
deleted and reset to factory defaults. Remove all cards; remove all the remote
control, restoration of all parameters, recovery management password 1234)
Management of the state
command table
Login *+Password+# default administrative password is 1234. Meanwhile the
orange light (MODE) to light
Log off. Operation **
mode light flash.
1. Add cards
add cards by entering
the card number 10+#+8-bit
card number.+# note card printed with
"0012345678" just enter the card can be after the 8 digit 12345678.
Add password 11+ #+4-8 digit password +#.
Add stress password 12+
#+4-8 digit password +#.
Add card quickly: -
20+#card reading. Note can continuously cards one by one.
Add card by self number:
- 21+#card reading+3
digit self-number.
Note: - easy to remember, for example room number could be the
self-number. if you need to add self -number continuously in press in press #
and redo steps above
Add wireless remote
control 22+#+ key on the remote
control transmitter.
Note: - to get such a function, a 433MHZ frequency
wireless module should be necessary.
Add Master Card:-23+#+ master card reading
Note: - in the non -management state after master
card reading once you can delete cards by reading. in the non-management state
after the master card reading two times you can add cards by reading.
Add card packaged
password 24+#+card reader +
card 4-8 digit password+#.
2. Delete
Delete
cards by reading 30+#+card reading
indicate :
the method can simultaneously read multiple consecutive delete the registered
cards, as in the reader to stop for 10 seconds, the program will automatically
exit the administrative state.
Delete cards by
number 31+#+8 digit card
number+#
Note:- if the card is printed with
"0012345678", just enter 12345678 can be deleted after the 8-bit
cards.
Delete
cards by self-numbering 32+#+3
digit self-number+#
Delete a wireless remote control 33+#+press the "send key"
Delete a wireless remote control 33+#+press the "send key"
Remove all wireless remote control 34+#
Delete a
password 35+# password+#
Delete a all
password 36+#
Delete all
data 40+#
Note:- the access controller will be formatted , such
as cards, passwords, wireless remote controls and other data will be removed
completely.
3. Edit the parameters.
Edit the administrator password:-60+#+4-8 digit new administrator password +# +4-8
digit new administrator password.
Note: - the new password
management change the password to confirm the new password twice, enter when
the password should be the same twice, or not successful.
Edit the open period tips:-63+#+ 3 digit open period+#
Note :- When the input
000 that means 0 second has been set equal to close the open period
prompts.(Maximum 999 second)
Edit the alarm time:-64+#+ 3 bit indicate the alarm time+#
Note: - enter 000 (the default),
turn off the alarm, enter 255 (255 is the maximum) the warning alarm would be
continuously.
Edit the open Delay
time:-66+#+ 3 bit open timeout+#
Note: - the input 000
means set to 0.5 seconds, the default is 3 seconds, the longest is 255 seconds.
Anti-detection
open password settings: - Operation types 68+#+1+2 bit error number+#
Note:- length of time
input 999 (The default) self-locking error 99 seconds 9.
4. Restore the factory
default
70+#
Note: - command input
all the parameters automatically after the restore the factory default values.(
Remove all cards , remove all the remote control , restoration of all
parameters, recovery management password:1234)
5. Keeping open and Quit
command
Set the electric lock
normally open:-83+#
Note: - after such an
operation electric locks will not lock. (You can also press & hold open
switch for 5 seconds to start the function)
Quit the electric lock
normally closed set:-84+#
Note: - After such an
operation to restore the default state. (You can also press & hold
"Open switch button" for 5 seconds to restore the default
state)
6. Data Management
Data backup:-91+#
Note the memory access
data backup to the backup memory.
Data recovery 92+#
Note a spare memory to
access memory data recovery (while the original data access memory will be
fully covered) memory model.